WALL ASSEMBLIES

JAMES HARDIE BUILDING PRODUCTS, INC. - Mission Viejo, CA USA



Show details for General InformationGeneral Information
Show details for DESIGN NO. JH/WA 60-01DESIGN NO. JH/WA 60-01
Show details for DESIGN NO. JH/WA 60-02DESIGN NO. JH/WA 60-02
Hide details for DESIGN NO. JH/WA 60-03DESIGN NO. JH/WA 60-03
DESIGN NO. JH/WA 60-03
NON-SYMMETRICAL, LIMITED LOAD-BEARING WALL ASSEMBLY
MAXIMUM LOAD - LESSER OF 800 LBS./STUD OR 31% OF FULL DESIGN LOAD
1.Wood Studs: Nominal 2" by 4" solid sawn wood studs located 16" oc. With two top plates and a single bottom plate.
2.Insulation: Minimum 3" thickness, 3 pcf mineral fiber batt insulation, conforming to ASTM-C665 Type I, friction fit in joist cavities.
3.Gypsum Wallboard, Side A: 5/8" Type X gypsum wallboard, oriented vertically and fastened with 1-7/8" Type S drywall screws, spaced 7" oc along board perimeter and in field areas of boards. Wallboard joints are staggered from those of opposite side of wall. Exposed gypsum wallboard joints shall be taped and filled.
4.Exterior Siding, Side B: 7/16" Titan® panel or Hardibacker® backerboard, oriented vertically and fastened with 1-1/2" No. 11 gauge roofing nails at 6" oc along joints and perimeter, and in field of boards. The fiber-cement board is covered with standard grade ceramic tile, nominal 1/4" thick.


Hide details for DESIGN NO. JH/WA 60-04DESIGN NO. JH/WA 60-04
DESIGN NO. JH/WA 60-04
NON-SYMMETRICAL LOAD-BEARING WALL ASSEMBLY
FULL DESIGN LOAD
1.Wood Studs: Nominal 2" by 4" solid sawn wood studs located 24" oc, with two top plates and a single bottom plate.
2.Insulation (Optional, Not Shown): R13 glass fiber batt insulation.
3.Gypsum Wallboard, Side A: 5/8" Type X gypsum wallboard, oriented vertically and fastened with 1-3/4" cup-head gypsum nails, spaced 7" oc at board edges and in field areas, or 1-1/2" Type S drywall screws, spaced 8" oc at board edges and in field areas of boards.
Gypsum Sheathing, Side B: 1/2" Type X or 5/8" Type X gypsum sheathing fastened with 1-3/4" long roofing nails spaced 7" oc. Sheathing edge joints shall be staggered from those on opposite sides of the wall.
4.Fibre-cement Exterior Siding: 5/16" thick Hardiplank® lapsiding, applied horizontally with a 1-1/4" headlap and fastened with a single 6d corrosion resistant common nail driven through the lapped planks at each stud location.
Show details for DESIGN NO. JH/WA 60-05DESIGN NO. JH/WA 60-05
Show details for DESIGN NO. JH/WA 60-06DESIGN NO. JH/WA 60-06
Hide details for DESIGN NO. JH/WA 60-07DESIGN NO. JH/WA 60-07
DESIGN NO. JH/WA 60-07
NON-SYMMETRICAL, NON-LOAD-BEARING WALL ASSEMBLY
1.Steel Studs: Minimum 3-5/8" depth, 25 gauge galvanized steel studs, spaced 16" oc.
2.Insulation: Minimum 3" thickness, 3 pcf mineral fiber batt insulation (rockwool), conforming to ASTM-C665 Type I, friction fit in joist cavities.
3.Gypsum Wallboard, Side A: 5/8" Type X gypsum wallboard installed horizontally or vertically and fastened with minimum 1-1/4" Type S drywall screws, 8" oc at board perimeter and in field areas of boards.
4.Fibre-cement Board, Side B: 13/32" Hardibacker 500® backerboard, applied horizontally or vertically and fastened with minimum 1" long No. 8 by 0.323" HD ribbed furring screws, located 8" oc along board perimeter and in field areas of boards.
5.Ceramic Tile: Nominal 4" by 4" by 1/4" standard grade ceramic wall tile.
Show details for DESIGN NO. JH/WA 60-08DESIGN NO. JH/WA 60-08
Show details for DESIGN NO. JH/WA 60-09DESIGN NO. JH/WA 60-09
Show details for DESIGN NO. JH/WA 60-10DESIGN NO. JH/WA 60-10




Show details for Evaluated to the following...Evaluated to the following...