| ASTM |
 | The James Hardie Building Products siding and soffit products: Hardiplank® lapsiding, HardiflexÔ panel, Hardipanel® siding, Harditex® baseboard, Hardisoffit® panel, Hardishingle® cladding shingles, Hardishingle® notched panel, and Hardipanel® shiplap, comply with ASTM-C1186, Standard Specification for Grade II, Type A, Non-Asbestos Fire-Cement Flat Sheets. |
 | The James Hardie Building Products siding and soffit products: Harditrimr® XLD® board complies with ASTM-C1186, Standard Specification for Grade I, Type A, Non-Asbestos Fire-Cement Flat Sheets. |
 | The James Hardie Building Products lining board and underlayment products: Titan® panel, Hardibacker® backerboard, Hardibacker® underlayment, and Titan®-FR panel, comply with ASTM-C1288, Standard Specification for Grade II Discrete Non-Asbestos Fiber-Cement Interior Substrate Sheets, and with ANSI-A118.9 as cementitious backer units. |
 | The James Hardie Building Products lining board and underlayment product, Hardibacker 500® backerboard, complies with ASTM-C1288, Standard Specification for Grade II Discrete Non-Asbestos Fiber-Cement Interior Substrate Sheets, and with ANSI-A118.9 as cementitious backer units. |
 | The James Hardie Building Products siding and soffit products: Hardiplank® lapsiding, HardiflexÔ panel, Hardipanel® siding, Harditex® baseboard, Hardisoffit® panel, HardishingleÔ cladding shingles, HardishingleÔ notched panel, Hardipanel® shiplap, and Hadibacker® 1/4" underlayment, comply with ASTM-E84, Standard Test Method for Surface Burning Characteristics of Building Materials. Their ratings are as follows: FSI = 0, SDI = 5. |
 | The James Hardie Building Products siding and soffit product: Harditrim® XLD® board, complies with ASTM-E84, Standard Test Method for Surface Burning Characteristics of Building Materials. Its ratings are as follows: FSI = 0, SDI = 0. |
 | The James Hardie Building Products siding and soffit products: Hardiplank® lapsiding, HardiflexÔ panel, Hardipanel® siding, Harditex® baseboard, Hardisoffit® panel, HardishingleÔ cladding shingles, HardishingleÔ notched panel, Hardipanel® shiplap, and Hardibacker® 1/4" underlayment, comply with ASTM-E136, Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750°C. |
| ISO |
 | The James Hardie Building Products siding and soffit products: Hardiplank® lap siding, HardiflexÔ panel, Hardipanel® siding, Harditex® baseboard, Hardisoffit® panel, Hardishingle® cladding shingles, Hardishingle® notched panel, and Hardipanel® shiplap conform to the requirements of ISO-8336 Fibre-cement flat sheets, for classification as Category 3, Type A. |
 | The James Hardie Building Products exterior cladding product, Harditrim® XLD® board, conforms to the requirements of ISO-8336 for classification as Category 2, Type A. |
 | The James Hardie Building Products interior lining product, Hardibacker® (Hardibacker 250®) underlayment, conforms to the requirements of ISO-8336 for classification as Category 3, Type B. |
 | The James Hardie Building Products interior lining product, Hardibacker 500® backerboard, conforms to the requirements of ISO-8336 for classification as Category 2, Type B. |
| EN |
 | The James Hardie Building Products siding and soffit products: Hardiplank® lap siding, HardiflexÔ panel, Hardipanel® siding, Harditex® baseboard, Hardisoffit® panel, Hardishingle® cladding shingles, Hardishingle® notched panel, and Hardipanel® shiplap, conform to the requirements of EN-12467, Fibre-cement flat sheet – Product specifications and test methods, for classification as Category A, Class 2. |
 | The James Hardie Building Products exterior cladding product, Harditrim® XLD® board, conforms to the requirements of EN-12467, Fibre-cement flat sheet – Product specifications and test methods, for classification as Category A, Class 1. |
 | The James Hardie Building Products interior lining product, Hardibacker® (Hardibacker 250®) underlayment, conforms to the requirements of EN-12467, Fibre-cement flat sheet – Product specifications and test methods, for classification as Category C, Class 3. |
 | The James Hardie Building Products interior lining product, Hardibacker 500® backerboard, conforms to the requirements of EN-12467, Fibre-cement flat sheet – Product specifications and test methods, for classification as Category C, Class 3. |
| CAN/CGSB |
 | The James Hardie Building Products siding products: Hardiplank® lap siding, HardishingleÔ cladding shingles, and HardishingleÔ notched panel, conform to the physical properties requirements of CAN/CGSB-34.4 Siding Asbestos-Cement, Shingles and Clapboards except that Hardiplank lap siding comes in 144" & 168" lengths with varying widths from 5-1/4" to 12""; Hardishingle™ cladding shingle come in lengths of 18” and widths of 6”, 8”, 12”; and Hardishingle™ notched panels come in lengths of 16”, 19” and a width of 48”. |
 | The James Hardie Building Products siding product, Hardipanel® siding, conforms to the physical properties requirements of CAN/CGSB-34.17 Sheets, Asbestos-Cement, Flat, Semicompressed except that density is 1320 kg/m3. |
| CAN/ULC-S102 |
 | The James Hardie Building Products siding and soffit products: Hardiplank® lap siding, HardiflexÔ panel, Hardipanel® siding, Harditex® baseboard, Hardisoffit® panel, Hardishingle® cladding shingles, Hardishingle® notched panel, Hardipanel® shiplap, Hardibacker® 1/4" underlayment, comply with CAN/ULC-S102, Method Of Test For Surface Burning Characteristics Of Building Materials And Assemblies. Their ratings are as follows: FSI = 0, SDI = 0. |
| CAN/ULC-S114 |
 | The James Hardie Building Products siding and soffit products: Hardiplank® lapsiding, HardiflexÔ panel, Hardipanel® siding, Harditex® baseboard, Hardisoffit® panel, Hardishingle® cladding shingles, Hardishingle® notched panel, Hardipanel® shiplap, and Hardibacker ® 1/4" underlayment, comply with CAN/ULC-S114, Standard Method of Test for Determination of Non-Combustibility in Building Materials. |